 ====== Bypass ====== ====== Bypass ======
-Bypass is used to trigger ​inputs ​for logics ​within a [[eyes:​flowcontrol:​queue|]] which come from logics ​outside a [[eyes:​flowcontrol:​group|]].  ​+Bypass is used to trigger ​the I/O for a logic within a [[eyes:​flowcontrol:​queue|]] which was produced by a logic outside a [[eyes:​flowcontrol:​group|]].  ​
  
 ===== Usage ===== ===== Usage =====
-In order to use the output of a logic, which is not created within the run of a Queue, Bypass will trigger this output ​to be fetched ​againTherefore, the I/O of the Queue is connected with the first input of the Bypass and the I/O of the needed ​logic is linked to the second input of Bypass. Then the first input of Bypass, which came from the last logic in the Queue, ​will be discarded. ​+In order to use the output of a logic, which is not created within the run of a [[eyes:​flowcontrol:​queue|Queue]], Bypass will trigger this I/O to be fetched ​every time Bypass is activatedThe I/O of the Queue is connected with the upper input of the Bypass ​element ​and the I/O of the required ​logic is linked to the second input of the element. Then the first input will be discarded. ​
  
 ===== Example ==== ===== Example ====
 {{ :​eyes:​flowcontrol:​bypass.png?​nolink&​800 |}} {{ :​eyes:​flowcontrol:​bypass.png?​nolink&​800 |}}
- +**Properties Window** 
-|< 100% 5% 35% >|+|< 100% 5% 30% >|
 ^                                       ​^ ​  ^ ^ ^                                       ​^ ​  ^ ^
-|{{:​eyes:​flowcontrol:​a.png?​nolink&​50 |}}| |The Bypass element is connected with the I/O from the logic [[eyes:​logics:​import|]], which passes this to the logic [[eyes:​logics:​boxmanipulation|]] . This element discards ​the I/O coming ​from the [[eyes:flowcontrol:queue|]].| +|{{:​eyes:​flowcontrol:​a.png?​nolink&​40 |}}| |The Bypass element is connected with the I/O from the logic [[eyes:​logics:​import|]] ​and the I/O coming from the [[eyes:​flowcontrol:​queue|]]. The first input of the element is discarded. The second input of the element is passed ​to the logic [[eyes:​logics:​boxmanipulation|]]. ​Each iteration Bypass is triggered and the input for [[eyes:​logics:​boxmanipulation|]] comes from the logic [[eyes:logics:import|]].| 
-|{{:​eyes:​flowcontrol:​b.png?​nolink&​50 |}}|{{:​eyes:​flowcontrol:​bypassqueque.png?​nolink |}}|The [[eyes:​flowcontrol:​queue|]] is used to rerun the the logic [[eyes:​logics:​boxmanipulation|]] ​with the I/O coming from the logic [[eyes:​logics:​import|]].|+|{{:​eyes:​flowcontrol:​b.png?​nolink&​40 |}}|{{:​eyes:​flowcontrol:​bypassqueque.png?​nolink&​800 ​|}}|The [[eyes:​flowcontrol:​queue|]] is used to rerun the Bypass element and the logic [[eyes:​logics:​boxmanipulation|]] ​for three iteration cycles.|
  
 ===== Parameters and I/O ==== ===== Parameters and I/O ====